4 Potted Hydrangea plants should be applied with different fertilizers in different growth stages. Nitrogen fertilizer is the main form in early spring. Phosphorus and potassium fertilizers are the main form during the buds, and they should be promptly removed after flowering. Winter fertilization should be avoided. °C about indoor wintering.

5 Hydrangea is mainly harmed by anthrax, and should always be treated with thiophanate dilution.

Portable Color Doppler Ultrasound Series

Color Doppler Ultrasound System
-High definition image
-Very thin light and pretty
-15inch LED Screen
-Built-in Battery

-Abundant function Multilingual

Specifications
1. Imaging Modes:
-B, B|B, 4B, B|M, M
-Color Doppler (CFM)
-Power Doppler (PDI)
-Directional Power Doppler (DPDI)
-Pulsed Wave Doppler (PWD)
-B+PWD (Duplex)
-B+CFM/PDI/DPDI+PWD (Triplex)
-High Pulse Repetition Frequency (HPRF)
-Tissue Harmonic Imaging (THI)
2. Scanning Method: electronic linear, electronic convex, electronic micro-convex, scanning depth: 2-24cm
3. Color Doppler:
-PRF variable: 0.5-9 kHz
-Wall filter settings: 3 steps (5%, %10%, 15% PRF)
-Angle steering for linear transducers: ±10°
-Real-time spatial filter: 4 values
-CFM palette>10 maps
-PDI palette>10 maps
-B/Color priority control
-Color threshold control
-CFM baseline control
-Doppler frequency selection
-Color frame averaging
-Transparent Color Mapping (TCM)
4. Pulsed Wave Doppler:
-PRF variable: 1-10 kHz
-Wall filter settings: 16 steps (2.5%-20% PRF)
-Angle steering for linear transducers: ±10°
-Real-time trace line with automatic calculation of spectrum parameters
-Stereo sound: volume control
-PWD palette>10 maps
-Doppler frequency selection
5.Processing:
-High Line Density scan mode for better resolution
-8 sliders TGC Control
-Dynamic range>120 dB
-Overall gain control
-M - mode sweep speed control
-Acoustic power control
-Variable frame averaging
-Brightness, contrast
-Advanced gamma control
-Scan direction, rotation, up-down controls
-Negative / positive control
-Echo enhancement control
-Noise rejection function
-Speckle reduction
6. Image and video: AVI, JPG, BMP, PNG, TIF, DCM (DICOM)
7. General Measurements and Calculations: Distance, Length, Area, Circumference, Volume, Angle, Stenosis %, A/B Ratio, Velocity, Pressure Gradient (PG), Acceleration, Resistivity Index (RI), Heart Rate, Velocity Time Integral (VTI), etc.
8. Measurements and Calculations Software Packages: Obstetrics, Gynecology, Abdominal, Urology, Endocrinology, Vascular, Cardiology, etc.
9. Expansion interfaces:
-VGA, TV Interface
-USB2.0 Interface
-RJ-45 Network interface
-Support DeskJet printer, LaserJet printer, video printer

Portable Color Doppler Ultrasound,Portable Color Ultrasound Machine,Portable Color Ultrasound Equipment,Color Ultrasound Equipment For Clinic