Main technical performance of explosion-proof intrinsically safe sound level meter

Explosion-proof intrinsically safe sound level meter Model: HS5628BF
This instrument has two measurement methods:
1. Measurement method 1: Automatic measurement of Lp, Leq, LAE, Lmax, Lmin, E, DL. Measurement time can be set
It is 10s, 1min, 5min, 10min20min, 30min, 1h, 8h, 24h, Man (manual).
The measurement results can be displayed or printed, and the measurement data can be stored in 500 groups.
2. Measurement method 2: Continuously measure the equivalent continuous sound level Leq, and the measurement time interval can be set to 1s~10S.
The start time, end time and measurement interval of the measurement can be set via the panel buttons or via the computer.
The measurement results can be displayed or printed or transmitted to a computer for processing, and the measurement data can store 50,000 equivalent continuous sound levels.
3. Using digital detection technology to replace some traditional sound level meters, the stability and reliability are greatly improved.
Main technical performance
1 Microphone: Φ6.35mm (1/4′′) electret test condenser microphone, sensitivity is about 2mV/Pa,
Frequency range 20Hz~12.5kHz
2 Sound pressure level measurement range: 50dB ~ 145dB (A) 55dB ~ 145dB (C) 55dB ~ 145dB (Z)
(with 2mv/pa sensitivity microphone)
Peak C measurement range: 53dB~148dB
3 Sound exposure measurement range: 0.01~999.99Pa2h
4 Noise dose measurement range: 0%~99999%
5 Frequency range: 20kHz~10kHz
6 Frequency weighting: A-weighting, C-weighting, Z-weighting
7 Time weighting: fast (F), slow (S), Peak (C)
8 Detector characteristics: digital true rms detection, crest factor 3
9 Measurement time setting: Measurement mode 1:10s, 1min, 5min, 10min, 15min, 20min, 30min, 1h, 8h, 24h.
Man (manual). Clock: Automatically run in year, month, day, hour, minute and second.
Automatic measurement function: Lp, Leq, LAE, Lmax, Lmim, E, DL.
Measurement method 2: The measurement time interval is 1s~10s, and the Leq is automatically measured.
10 Automatic measurement data storage: Measurement mode 1: Single group: 500 groups of data, measurement method 2: 50000 Leq values.
11 Save and output to a computer for processing, display and print results.
12 Display: 122X32 dot matrix liquid crystal display with measurement mode, measurement time and clock, backlight display and other functions.
Output interface 13: stream output: 0V ~ 1.5V RS-232C interface output
14 Power supply: 3.7V/1000mA rechargeable lithium battery (filled in the lower case of the instrument, the battery with current limiting protection).
15 Dimensions: l × b × h (mm) 120 × 67 × 24
16 Quality: 300g (with battery) Working temperature: -10 ° C ~ 50 ° C, relative humidity 20% ~ 90%