Ysx500d Hospital Medical Fixed 500mA 50kw Digital X-ray Equipment

Model NO.: Ysx500D
Tube Volate: 40kv~150kv
Tube Current: 10mA~630mA
Time: 2ms~10s
Mas: 0.1mas~630mas
Working Frequency: ≥400kHz
Trademark: YSENMED
Transport Package: Wooden Box
Specification: 170*90*90
Origin: China
500mA Digital Radiography X-ray Machine
YSX500D


Ysx500d Hospital Medical Fixed 500mA 50kw Digital X-ray Equipment
Ysx500d Hospital Medical Fixed 500mA 50kw Digital X-ray Equipment
Ysx500d Hospital Medical Fixed 500mA 50kw Digital X-ray Equipment
 

1 High Frequency Generator

1.1 Functions: Digital x-ray radigography, x-ray filter radiography, buck stand radiography, ARP and AEC.

1.2 Nominal electric power: 50 kW

1.3 Tube volate: 40kV~150kV

1.4 Tube current: 10mA~630mA

1.5 Time: 2ms~10s

1.6 mAs: 0.1mAs~630mAs

1.7 Working frequency: ≥400kHz

1.8 Control panel: LCD touch screen

 

2 X-ray Tube

2.1 Max. Tube voltage: 150kV

2.2 Focus:Small focus:0.6mm; Big focus:1.2mm

2.3 Anode input power: small focus 19kW, big focus 50kW

2.4 Target angle: 12°

2.5 Anode RPM:2800rpm

2.6 Heat capacity: 150kHU

 

3 Flat Panel Detector

3.1 GOS & Csl

3.2 Size: 35×43cm(14×17 inch)

3.3 Pixel: 140μm

3.4 Pixel matrix: 2560×3072

3.5 A/D conversion: 16Bit

4 Radiography Table

4.1 Size: 2100mm×825mm×655mm (LxWxH)

4.2 Horizontal moving range: ≥250mm;

4.3 Lengthways moving range: ≥825mm;

4.4 Table top lock: Electromagnetic lock, braking force≥100N, with pedal switch, flexible and convenient.

4.5 With electric or manual control of mechanical movement, and there is automatic tracking alignment function with the x-ray tube and the detector.

4.6 Grid size: ≥15"×18";Grid focus distance: f0=100cm; Grid ratio: r=10 :1;Grid density: N=103Lines/Inch

 

4.7 Tube Column

4.7.1 Secure and solid structure

4.7.2 Column rotation: ≥±180°

4.7.3 Moving range along the table: ≥1575mm, can be locked at any point

4.7.4 Tube moving up & down: 930mm±10mm, an be locked at any point

4.7.5 Tube rotation: ≥±180°

4.7.6 Max. Distance from tube focus to film: ≥1200mm.

 

5 Bucky Stand

5.1 Up & Down moving range: ≥1200mm;

5.2 At max. Height, the distance between the floor and the box center is ≥1500 mm;

5.3 Grid size: 18×18";Grid focus: f0=180cm;Grid ratio: r=10 :1;Grid density: N=103Lines/Inch

 

6 Collimator: Flexible and convenient to operate, and any rectangle radiography field size is available. 

 

Packing List (YSX500D)

 
Ysx500d Hospital Medical Fixed 500mA 50kw Digital X-ray Equipment
Ysx500d Hospital Medical Fixed 500mA 50kw Digital X-ray Equipment
  




Ysx500d Hospital Medical Fixed 500mA 50kw Digital X-ray Equipment



 

We have about more than ten years of making the PVC Hose . We all use the virgin granules to make the hose to ensure the quality. We also make the granules ourselves, So we can give you more lower price. All kinds of PVC hose can be Customized. It can be used widely. It can be used as Pvc Garden Hose, Pvc Gas Hose , PVC Air Hose , PVC Braided Hose, PVC Spray Hose, High Pressure PVC Braided Tubing and so on. It can be used for conveying of air, gas and water in industry, agriculture, construction, engineering and machinery etc.


PVC Hose

Flexible Pvc Pipe,PVC Braided Hose,PVC Spray Hose,High Pressure PVC Braided Tubing

JiangYin ZhengMei Mechanical Equipment CO.,LTD. , http://www.zm-pvchose.com